Thermal Process Technology - Chamber Dryer, Electrically Heated or Gas-Fired - Nabertherm ipari kemence gyártás
Brazil 中文 Cesky Deutsch English
Español Francais Greek Hungarian Italiano
Nederlands Polski Português Pусский Swedish
Türkçe 日本語 Dansk

Company Video
video high res video low res

Chamber Dryer Electrically Heated or Gas-Fired
KTR 8000 Standard models

Production system for tempering silicone, consisting of four chamber dryers for moving the load during heat treatment along with a three-stage heat exchanger to optimize energy efficiency

Motor-driven rotary rack with baskets for moving the charge during heat treatment

Air-circulation in the chamber dryer

Adjustable outflow openings as additional equipment

The chamber dryers of the KTR range can be used for complex drying processes and heat treatment of charges of normal weight and packing density to an application temperature of 260 °C. The high-performance air circulation enables optimum temperature uniformity throughout the usable space. A wide range of accessories allow the furnace to be modified to meet specific process requirements. The design for the heat treatment of combustible materials in conformance with EN 1539 is available for all sizes.

  • Tmax 260 °C
  • Electrically heated (via a heating register with integrated chrome steel heating elements) or gas-fired (direct gas heating including injection of the hot air into the intake duct)
  • Optimum temperature uniformity up to + 3 K according to DIN 17052-1
  • High-quality mineral wool insulation provides for outer temperatures of < 20 °C above room temperature
  • High air exchange for fast drying processes
  • Double-wing door for furnaces KTR 3100 and larger
  • Over-temperature limit controller with manual reset for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the dryer and load
  • Incl. floor insulation

Additional equipment

  • Entry ramp for pallet trucks or track cutouts for charging trolley
  • Optimal air circulation for individual charges by means of adjustable air outlets
  • Fan system for faster cooling with manual or automatic control
  • Manually adjustable intake and exhaust air vents
  • Programmed opening and closing of exhaust vents
  • Observation window and furnace chamber lighting
  • Safety technology according to EN 1539 for charges containing solvents
  • Catalytic or thermal exhaust gas cleaning systems
  • Custom-built sizes
  • Tightly welded inner housing
  • Process control and documentation with Controltherm MV software package
ModelTmaxInner dimensions in mmVolumeOuter dimensions in mmConnectedElectrical
 °Cwdhin lWDHload/kWconnection*
KTR 1500260100010001500150019102315142021three-phase
KTR 3100260125012502000310021602850167030three-phase
KTR 4500260150015002000450024102850192050three-phase
KTR 6125260175017502000612526603000217050three-phase
KTR 8000260200020002000800029103000242065three-phase
*Please see page 66 for more information about supply voltage